{"product_id":"hayward-aquarite-low-salt-main-pcb-glx-pcb-ls-cul","title":"Hayward AquaRite Low Salt Main PCB GLX-PCB-LS-CUL – 120V\/240V","description":"\u003cdiv class=\"ups-product-desc\" style=\"max-width: 100%; color: #1f2937; line-height: 1.7;\"\u003e\n\u003c!-- HERO --\u003e\n\u003cdiv style=\"background: linear-gradient(135deg,#0f4c81 0%,#1273b8 100%); color: #fff; border-radius: 18px; padding: 24px 20px; margin: 0 0 24px;\"\u003e\n\u003cdiv style=\"font-size: 13px; text-transform: uppercase; opacity: .9; margin-bottom: 8px;\"\u003eSalt Chlorinator Replacement Circuit Board\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 10px; font-size: 30px; color: #fff;\"\u003eHayward AquaRite Low Salt Main PCB – 120V\/240V\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 16px; color: #fff;\"\u003eGenuine Hayward replacement main circuit board for compatible AquaRite Low Salt and standard AquaRite salt chlorination systems. Supports 120V and 240V configurations and ships factory-configured for 240V operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- WARRANTY --\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 14px; padding: 16px; margin-bottom: 28px;\"\u003e\n\u003ch3 style=\"margin: 0 0 8px; font-size: 22px; color: #1e3a8a;\"\u003eWarranty Information\u003c\/h3\u003e\n\u003cp style=\"margin: 0; font-size: 16px;\"\u003e\u003cstrong\u003e6-Month Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 6px 0 0; font-size: 14px; color: #475569;\"\u003eUltimate Pools is your first point of contact for compatibility verification, installation guidance, and warranty support.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- INTRO --\u003e\n\u003cdiv style=\"margin-bottom: 28px;\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eHayward AquaRite Low Salt Main PCB (GLX-PCB-LS-CUL)\u003c\/strong\u003e is a genuine Hayward replacement printed circuit board designed for compatible AquaRite Low Salt and standard AquaRite salt chlorine generator control units. The main PCB is an internal electronic component responsible for essential salt chlorination control functions, including operation of the connected salt cell.\u003c\/p\u003e\n\u003cp\u003eThis replacement board supports \u003cstrong\u003e120V and 240V electrical configurations\u003c\/strong\u003e and is supplied from the factory configured for \u003cstrong\u003e240V operation\u003c\/strong\u003e. For compatible 120V installations, the voltage configuration is changed by repositioning the jumpers on the terminal block according to the diagram inside the AquaRite control enclosure. The GLX-PCB-LS-CUL provides a replacement option when the existing main circuit board has been diagnosed as defective. Professional installation and verification of the correct electrical configuration are recommended.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- FEATURES --\u003e\n\u003cdiv style=\"margin-bottom: 32px;\"\u003e\n\u003ch3 style=\"font-size: 26px; margin: 0 0 18px; color: #0f172a;\"\u003eKey Features\u003c\/h3\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(240px,1fr)); gap: 12px;\"\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #dbeafe; border-radius: 14px; padding: 16px;\"\u003e\n\u003cstrong\u003eGenuine Hayward Replacement\u003c\/strong\u003e\u003cbr\u003eOriginal Hayward replacement main printed circuit board identified by manufacturer part number GLX-PCB-LS-CUL.\u003c\/div\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #dbeafe; border-radius: 14px; padding: 16px;\"\u003e\n\u003cstrong\u003eAquaRite Low Salt Compatibility\u003c\/strong\u003e\u003cbr\u003eDesigned for compatible Hayward AquaRite Low Salt salt chlorination control systems.\u003c\/div\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #dbeafe; border-radius: 14px; padding: 16px;\"\u003e\n\u003cstrong\u003eStandard AquaRite Compatibility\u003c\/strong\u003e\u003cbr\u003eAlso supports the specified standard AquaRite models, including compatible W3-suffix systems.\u003c\/div\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #dbeafe; border-radius: 14px; padding: 16px;\"\u003e\n\u003cstrong\u003e120V\/240V Configuration\u003c\/strong\u003e\u003cbr\u003eSupports both 120V and 240V installations when configured correctly for the equipment's electrical supply.\u003c\/div\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #dbeafe; border-radius: 14px; padding: 16px;\"\u003e\n\u003cstrong\u003eFactory-Set for 240V\u003c\/strong\u003e\u003cbr\u003eShips with the voltage jumpers positioned for 240V operation.\u003c\/div\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #dbeafe; border-radius: 14px; padding: 16px;\"\u003e\n\u003cstrong\u003eTerminal Block Jumper Configuration\u003c\/strong\u003e\u003cbr\u003eVoltage selection is performed using the terminal block jumpers and the wiring diagram inside the control enclosure.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- COMPATIBILITY --\u003e\n\u003cdiv style=\"margin-bottom: 32px;\"\u003e\n\u003ch3 style=\"font-size: 26px; margin: 0 0 16px; color: #0f172a;\"\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #dbeafe; border-radius: 14px; padding: 18px;\"\u003e\n\u003cp style=\"margin: 0 0 14px;\"\u003eCompatible with the following Hayward AquaRite salt chlorination system models:\u003c\/p\u003e\n\u003cul style=\"margin: 0; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eHayward AquaRite Low Salt:\u003c\/strong\u003e AQR-LS-CUL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHayward AquaRite:\u003c\/strong\u003e AQR-CUL, AQR3CUL, AQR9CUL, AQR15CUL, AQR925-CUL, AQR940-CUL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHayward W3 AquaRite:\u003c\/strong\u003e AquaRite systems with W3-suffix model designations, as specified in the supplied compatibility information\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin: 16px 0 0; font-size: 14px; color: #475569;\"\u003e\u003cstrong\u003eAdditional System Reference:\u003c\/strong\u003e Hayward Goldline OnCommand automation is also referenced in the supplied compatibility information. However, a specific OnCommand model number and its confirmed PCB fitment have not been provided. Verify the manufacturer's replacement parts documentation before ordering for an OnCommand installation.\u003c\/p\u003e\n\u003cp style=\"margin: 16px 0 0; font-size: 14px; color: #475569;\"\u003e\u003cstrong\u003eVoltage Requirement:\u003c\/strong\u003e The GLX-PCB-LS-CUL ships factory-configured for \u003cstrong\u003e240V\u003c\/strong\u003e. For a compatible 120V installation, the terminal block jumpers must be repositioned according to the wiring diagram inside the control enclosure. This work should be performed by a qualified professional.\u003c\/p\u003e\n\u003cp style=\"margin: 16px 0 0; font-size: 14px; color: #475569;\"\u003e\u003cstrong\u003eFitment Note:\u003c\/strong\u003e This replacement board is intended for the specified AquaRite systems. Do not assume compatibility with AquaRite XL, AquaRite Pro or other Hayward control systems solely because they use similar circuit boards. Verify the existing PCB part number and control unit model before ordering.\u003c\/p\u003e\n\u003cp style=\"margin: 16px 0 0; font-size: 14px; color: #475569;\"\u003eCompatibility may vary by production year, configuration and installation. Verify your exact model and part number before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- APPLICATIONS --\u003e\n\u003cdiv style=\"margin-bottom: 32px;\"\u003e\n\u003ch3 style=\"font-size: 26px; margin: 0 0 16px; color: #0f172a;\"\u003eApplications\u003c\/h3\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #dbeafe; border-radius: 14px; padding: 18px;\"\u003e\n\u003cul style=\"margin: 0; padding-left: 20px;\"\u003e\n\u003cli\u003eReplacement of defective Hayward AquaRite Low Salt main circuit boards\u003c\/li\u003e\n\u003cli\u003eRepair of compatible standard AquaRite salt chlorination control units\u003c\/li\u003e\n\u003cli\u003eMain PCB replacement in specified AQR-CUL and AQR-LS-CUL systems\u003c\/li\u003e\n\u003cli\u003eServicing compatible AquaRite AQR3CUL, AQR9CUL and AQR15CUL systems\u003c\/li\u003e\n\u003cli\u003eReplacement of main circuit boards in compatible AQR925-CUL and AQR940-CUL systems\u003c\/li\u003e\n\u003cli\u003eProfessional repair of compatible 120V or 240V AquaRite installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin: 16px 0 0; font-size: 14px; color: #475569;\"\u003eA salt chlorination system malfunction does not necessarily indicate a defective main PCB. Confirm the cause through appropriate diagnostics before replacing the circuit board. Hayward recommends photographing the original PCB wiring before disconnecting any connections to assist with correct reinstallation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- INSTALLATION --\u003e\n\u003cdiv style=\"margin-bottom: 32px;\"\u003e\n\u003ch3 style=\"font-size: 26px; margin: 0 0 16px; color: #0f172a;\"\u003eProfessional Installation Recommended\u003c\/h3\u003e\n\u003cdiv style=\"background: #fff7ed; border: 1px solid #fdba74; border-radius: 14px; padding: 18px;\"\u003e\n\u003cp style=\"margin: 0 0 12px;\"\u003e\u003cstrong\u003eElectrical Component – Qualified Professional Installation Recommended\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 12px;\"\u003eThe Hayward GLX-PCB-LS-CUL is an electrical control board intended for installation inside a compatible AquaRite salt chlorination control enclosure. Installation should be completed by a qualified pool equipment technician or licensed electrical professional familiar with Hayward salt chlorination systems.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 12px;\"\u003e\u003cstrong\u003eImportant Voltage Configuration:\u003c\/strong\u003e This PCB ships from the factory set for 240V operation. When installing in a compatible 120V system, the terminal block jumpers must be repositioned according to the manufacturer's wiring diagram located inside the control enclosure. Never energize the board until the supply voltage and jumper configuration have been verified.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 12px;\"\u003e\u003cstrong\u003eHayward Expert Tip:\u003c\/strong\u003e Take a clear photograph of the existing PCB wiring and connector positions before disconnecting the original board. This provides a reference during installation of the replacement PCB.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eDisconnect and verify isolation of all electrical power before opening the control enclosure or handling the circuit board. Installation must follow the manufacturer's instructions and all applicable electrical, plumbing, bonding and building codes. Verify the wiring connections, voltage configuration and system operation before returning the equipment to service.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- SPECIFICATIONS --\u003e\n\u003cdiv style=\"margin-bottom: 28px;\"\u003e\n\u003ch3 style=\"font-size: 26px; margin: 0 0 16px; color: #0f172a;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; border: 1px solid #e5e7eb; border-radius: 14px;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 520px; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003eGLX-PCB-LS-CUL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003eHayward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003eSalt Chlorinator Main Printed Circuit Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eSystem Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003eAquaRite Low Salt \/ AquaRite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eSupported Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e120V \/ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eFactory Voltage Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eVoltage Configuration Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003eTerminal block jumper positioning according to the control enclosure wiring diagram\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003eMain circuit board replacement for compatible AquaRite salt chlorination control units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003eHayward AQR-LS-CUL, AQR-CUL, AQR3CUL, AQR9CUL, AQR15CUL, AQR925-CUL, AQR940-CUL and specified W3-suffix AquaRite systems. OnCommand fitment requires additional verification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e6-Month Manufacturer Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px;\"\u003e\u003cstrong\u003eFinal Sale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003cdiv\u003e\n\u003ch3 style=\"font-size: 26px; margin: 0 0 16px; color: #0f172a;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdiv style=\"background: #fff; border: 1px solid #e5e7eb; border-radius: 14px; overflow: hidden;\"\u003e\n\u003cdiv style=\"padding: 16px; border-bottom: 1px solid #e5e7eb;\"\u003e\n\u003cstrong\u003eWhich Hayward AquaRite models are compatible with GLX-PCB-LS-CUL?\u003c\/strong\u003e\u003cbr\u003eThe GLX-PCB-LS-CUL is listed for AQR-LS-CUL, AQR-CUL, AQR3CUL, AQR9CUL, AQR15CUL, AQR925-CUL, AQR940-CUL and W3-suffix AquaRite systems. Confirm the existing circuit board part number and exact control unit model before ordering.\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px; border-bottom: 1px solid #e5e7eb;\"\u003e\n\u003cstrong\u003eDoes the GLX-PCB-LS-CUL arrive configured for 120V or 240V?\u003c\/strong\u003e\u003cbr\u003eThe board ships from the factory configured for 240V operation. For a compatible 120V installation, a qualified professional must reposition the terminal block jumpers according to the diagram inside the control enclosure.\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px; border-bottom: 1px solid #e5e7eb;\"\u003e\n\u003cstrong\u003eCan this replacement board be used in both 120V and 240V installations?\u003c\/strong\u003e\u003cbr\u003eYes. The GLX-PCB-LS-CUL supports both voltage configurations when correctly configured. The electrical supply and jumper positions must be verified before energizing the system.\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px; border-bottom: 1px solid #e5e7eb;\"\u003e\n\u003cstrong\u003eWhat should I do before disconnecting my original AquaRite circuit board?\u003c\/strong\u003e\u003cbr\u003eHayward recommends taking a clear photograph of the existing PCB wiring before removing any connections. This helps document the original wiring arrangement for the replacement installation. Always disconnect and verify isolation of electrical power before servicing the equipment.\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px;\"\u003e\n\u003cstrong\u003eWhat is the warranty and return policy?\u003c\/strong\u003e\u003cbr\u003eThe Hayward GLX-PCB-LS-CUL includes a 1-year manufacturer warranty and is a final sale replacement part. Confirm the required PCB part number, control unit compatibility and electrical configuration before purchasing.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":40480405749929,"sku":"GLX-PCB-LS-CUL","price":709.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0553\/2647\/4409\/products\/GLX-PCB-LS-CUL.jpg?v=1621282845","url":"https:\/\/ultimatepools.ca\/products\/hayward-aquarite-low-salt-main-pcb-glx-pcb-ls-cul","provider":"ultimatepools.ca","version":"1.0","type":"link"}