{"product_id":"hayward-main-pcb-glx-pcb-pro","title":"Hayward Main PCB GLX-PCB-PRO – for ProLogic \u0026 AquaPlus","description":"\u003cdiv class=\"ups-product-desc\" style=\"max-width: 100%; color: #1f2937; line-height: 1.7;\"\u003e\n\u003c!-- HERO --\u003e\n\u003cdiv style=\"background: linear-gradient(135deg,#0f4c81 0%,#1273b8 100%); color: #fff; border-radius: 18px; padding: 24px 20px; margin: 0 0 24px;\"\u003e\n\u003cdiv style=\"font-size: 13px; text-transform: uppercase; opacity: .9; margin-bottom: 8px;\"\u003ePool Automation Replacement Board\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 10px; font-size: 30px; color: #fff;\"\u003eHayward Main PCB Replacement Board\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 16px; color: #fff;\"\u003eGenuine Hayward replacement main control board for compatible ProLogic, AquaPlus and AquaLogic PS Series automation systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- WARRANTY --\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 14px; padding: 16px; margin-bottom: 28px;\"\u003e\n\u003ch3 style=\"margin: 0 0 8px; font-size: 22px; color: #1e3a8a;\"\u003eWarranty Information\u003c\/h3\u003e\n\u003cp style=\"margin: 0; font-size: 16px;\"\u003e\u003cstrong\u003e1-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 6px 0 0; font-size: 14px; color: #475569;\"\u003eUltimate Pools is your first point of contact for compatibility verification, installation guidance, and warranty support.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- INTRO --\u003e\n\u003cdiv style=\"margin-bottom: 28px;\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eHayward Main PCB Replacement Board (\u003cmeta charset=\"utf-8\"\u003eGLX-PCB-PRO)\u003c\/strong\u003e is a genuine Hayward replacement main control board for compatible ProLogic, AquaPlus and AquaLogic automation systems. It is designed for PS Series AquaLogic and ProLogic systems across all versions and date codes, subject to the specific fitment exclusion noted below.\u003c\/p\u003e\n\u003cp\u003eThe newest revision of the GLX-PCB-PRO also supports Low Salt operation through a specific button sequence. Because this is the primary electronic control board for the automation system and connector configurations must match, verify the existing system model before ordering and have the board professionally installed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- FEATURES --\u003e\n\u003cdiv style=\"margin-bottom: 32px;\"\u003e\n\u003ch3 style=\"font-size: 26px; margin: 0 0 18px; color: #0f172a;\"\u003eKey Features\u003c\/h3\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(240px,1fr)); gap: 12px;\"\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #dbeafe; border-radius: 14px; padding: 16px;\"\u003e\n\u003cstrong\u003eGenuine Hayward Replacement\u003c\/strong\u003e\u003cbr\u003eGenuine replacement main PCB designed for compatible Hayward automation systems.\u003c\/div\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #dbeafe; border-radius: 14px; padding: 16px;\"\u003e\n\u003cstrong\u003ePS Series Compatibility\u003c\/strong\u003e\u003cbr\u003eDesigned for compatible PS Series AquaLogic and ProLogic automation systems.\u003c\/div\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #dbeafe; border-radius: 14px; padding: 16px;\"\u003e\n\u003cstrong\u003eAll Versions \u0026amp; Date Codes\u003c\/strong\u003e\u003cbr\u003eCompatible with supported AquaLogic and ProLogic systems regardless of version or date code.\u003c\/div\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #dbeafe; border-radius: 14px; padding: 16px;\"\u003e\n\u003cstrong\u003eAquaPlus Applications\u003c\/strong\u003e\u003cbr\u003eReplacement main control board for compatible Hayward AquaPlus automation systems.\u003c\/div\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #dbeafe; border-radius: 14px; padding: 16px;\"\u003e\n\u003cstrong\u003eLow Salt Operation\u003c\/strong\u003e\u003cbr\u003eThe newest board revision allows Low Salt operation through a specific button sequence.\u003c\/div\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #dbeafe; border-radius: 14px; padding: 16px;\"\u003e\n\u003cstrong\u003eModel-Specific Fitment\u003c\/strong\u003e\u003cbr\u003eConnector and pin alignment must match the existing system; AQL-P-4-CUL is specifically excluded.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- COMPATIBILITY --\u003e\n\u003cdiv style=\"margin-bottom: 32px;\"\u003e\n\u003ch3 style=\"font-size: 26px; margin: 0 0 16px; color: #0f172a;\"\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #dbeafe; border-radius: 14px; padding: 18px;\"\u003e\n\u003cp style=\"margin: 0 0 14px;\"\u003eThe GLX-PCB-PRO is designed for compatible Hayward automation systems including:\u003c\/p\u003e\n\u003cul style=\"margin: 0; padding-left: 20px;\"\u003e\n\u003cli\u003eHayward ProLogic PS Series systems - all versions and date codes\u003c\/li\u003e\n\u003cli\u003eHayward AquaLogic PS Series systems - all versions and date codes\u003c\/li\u003e\n\u003cli\u003eCompatible Hayward AquaPlus systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background: #fff7ed; border: 1px solid #fdba74; border-radius: 10px; padding: 14px; margin-top: 16px;\"\u003e\n\u003cstrong style=\"color: #9a3412;\"\u003eImportant Fitment Exclusion:\u003c\/strong\u003e\n\u003cp style=\"margin: 6px 0 0;\"\u003eThe GLX-PCB-PRO cannot be used with the \u003cstrong\u003eAQL-P-4-CUL\u003c\/strong\u003e model because the pins do not align.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin: 16px 0 0; font-size: 14px; color: #475569;\"\u003eCompatibility may vary by production year, configuration and installation. Verify your exact model and part number before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- APPLICATIONS --\u003e\n\u003cdiv style=\"margin-bottom: 32px;\"\u003e\n\u003ch3 style=\"font-size: 26px; margin: 0 0 16px; color: #0f172a;\"\u003eApplications\u003c\/h3\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #dbeafe; border-radius: 14px; padding: 18px;\"\u003e\n\u003cul style=\"margin: 0; padding-left: 20px;\"\u003e\n\u003cli\u003eReplacement of a compatible ProLogic main control board\u003c\/li\u003e\n\u003cli\u003eReplacement of a compatible AquaLogic PS Series main control board\u003c\/li\u003e\n\u003cli\u003eReplacement of a compatible AquaPlus main control board\u003c\/li\u003e\n\u003cli\u003eSupported Low Salt operation with the newest board revision\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin: 16px 0 0; font-size: 14px; color: #475569;\"\u003eConfirm the automation-system model and existing board configuration before ordering. The AQL-P-4-CUL is not compatible with this replacement board.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- INSTALLATION --\u003e\n\u003cdiv style=\"background: #fff7ed; border: 1px solid #fdba74; border-radius: 14px; padding: 18px; margin-bottom: 32px;\"\u003e\n\u003ch3 style=\"margin: 0 0 10px; font-size: 22px; color: #9a3412;\"\u003eProfessional Installation Recommended\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eThis is an electrical control-board replacement. Installation must follow Hayward manufacturer instructions and all applicable electrical, plumbing, bonding and building codes. Power must be disconnected before servicing the control system. Professional installation by a qualified pool technician or licensed electrician is recommended.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- SPECIFICATIONS --\u003e\n\u003cdiv style=\"margin-bottom: 28px;\"\u003e\n\u003ch3 style=\"font-size: 26px; margin: 0 0 16px; color: #0f172a;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; border: 1px solid #e5e7eb; border-radius: 14px;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 520px; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003eGLX-PCB-PRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003eHayward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003eMain PCB \/ Automation Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003ePool \u0026amp; Spa Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003eProLogic PS Series and AquaLogic PS Series - all versions and date codes; compatible AquaPlus systems. Not compatible with AQL-P-4-CUL due to pin alignment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eLow Salt Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003eSupported by newest revision through a specific button sequence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #e5e7eb;\"\u003e1-Year Manufacturer Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px;\"\u003e\u003cstrong\u003eFinal Sale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px;\"\u003e\u003cstrong\u003eManual\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e\u003ca style=\"color: #1d4ed8; font-weight: 600; text-decoration: none;\" rel=\"noopener noreferrer\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0553\/2647\/4409\/files\/GLX-PCB-PRO_Manual.pdf?v=1790189402\" target=\"_blank\"\u003eDownload Product Manual\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003cdiv\u003e\n\u003ch3 style=\"font-size: 26px; margin: 0 0 16px; color: #0f172a;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdiv style=\"background: #fff; border: 1px solid #e5e7eb; border-radius: 14px; overflow: hidden;\"\u003e\n\u003cdiv style=\"padding: 16px; border-bottom: 1px solid #e5e7eb;\"\u003e\n\u003cstrong\u003eWhat systems is the GLX-PCB-PRO designed for?\u003c\/strong\u003e\u003cbr\u003eThe board is designed for compatible Hayward ProLogic and AquaLogic PS Series systems across all versions and date codes, as well as compatible AquaPlus systems.\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px; border-bottom: 1px solid #e5e7eb;\"\u003e\n\u003cstrong\u003eWill the GLX-PCB-PRO work with an AQL-P-4-CUL?\u003c\/strong\u003e\u003cbr\u003eNo. The AQL-P-4-CUL is specifically excluded because its pins do not align with the GLX-PCB-PRO.\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px; border-bottom: 1px solid #e5e7eb;\"\u003e\n\u003cstrong\u003eDoes this board support Low Salt operation?\u003c\/strong\u003e\u003cbr\u003eThe newest revision of the GLX-PCB-PRO supports Low Salt operation through a specific button sequence.\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px; border-bottom: 1px solid #e5e7eb;\"\u003e\n\u003cstrong\u003eShould the GLX-PCB-PRO be professionally installed?\u003c\/strong\u003e\u003cbr\u003eYes. This is an electrical automation control board, so professional installation is recommended. Installation must follow Hayward instructions and applicable electrical and bonding requirements.\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px;\"\u003e\n\u003cstrong\u003eIs the GLX-PCB-PRO final sale?\u003c\/strong\u003e\u003cbr\u003eYes. This replacement control board is final sale, so verify the exact automation-system model and existing board configuration before ordering.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":43105182843049,"sku":"GLX-PCB-PRO","price":1812.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0553\/2647\/4409\/files\/glx-pcb-pro.png?v=1686849792","url":"https:\/\/ultimatepools.ca\/products\/hayward-main-pcb-glx-pcb-pro","provider":"ultimatepools.ca","version":"1.0","type":"link"}